HOPEX IRM > HOPEX IRM Common Features > Managing Key Indicators > Defining Measurement Frequency and Notifications
Defining Measurement Frequency and Notifications
Specifying Measurement Frequency
To specify the measurement frequency of an indicator:
2. In the properties of a key indicator, select the Values page.
3. In the Measurement frequency section, select a steering calendar:
Daily Measurement Frequency
Monthly Measurement Frequency
Weekly Measurement Frequency
This steering calendar is used to send notifications to appropriate users.
Managing Notifications
HOPEX IRM enables to send automatic notifications based on:
the key indicator status
the last measurement date
The Time to Failure value (number of days)
This way, you can ensure that the indicator owners properly manage indicators.
To specify or modify user notifications:
2. In the properties of a key indicator, select the Notifications page.
You can choose to send periodic notifications:
to a specific person
*By default, the owner of a key indicator receives notifications. Here you can specify another person.
*The notifications sent to appropriate users prompts them to enter values for the key indicator they are in charge of monitoring. For more details, see Entering Periodic Key Indicator Values.
to a set of users (when the indicator reaches a specified status or when the last measurement is older than a specified number of days).
Entering Periodic Key Indicator Values
HOPEX IRM enables the indicator owner or other authorized persons to manually enter key indicator values in order to feed the key indicator.
It is also possible to feed automatically the key indicator.
Entering a key indicator value manually
To enter a key indicator value:
2. In the properties of a key indicator, select the Values page.
3. Expand the Values section and click New to enter a value.
4. Modify the default date if necessary.
5. Click OK.
*Notifications can be set up so that you are periodically reminded of the need of entering periodic values. For more details, see Managing Notifications.
The values entered periodically enable to produce the value which is indicated in the key indicator Characteristics page.
Parameterizing automatic value entering
It is also possible to feed automatically the key indicator.
To do this:
2. In the properties of a key indicator, select the Values page.
3. In the Measurement Parameters section, select the Measurement Frequency through a steering calendar.
4. Select the Indicator Value Computation Logic.
5. (optional) If the selected computation logic requires parameters, specify the query in the Computation Parameters field.
Query =
ObjectParameter =
A button enables you to Test the calculation.